The following are known issues in our latest release
Unexpected crashes and rendering are noticed on Firefox.
Chrome is the currently recommended browser. We will bring support to Firefox in one of the future releases.
Online/Offline connection status on stream window is not updated immediately.
Wait for 30 sec or refresh the page.
When a use case commissioning action errors out, the program currently tries indefinitely to auto-restore it. This might lead Nimble to end up in an unfavorable state.
When use case commissioning errors out, please delete the errored out use case and re-deploy manually with the error rectified.
Nimble may buffer up to, by default, 30 frames per channel before dropping data. When the network is congested these buffers may fill up causing high latency.
Update the environment section of the docker-compose.yaml file to specify the following variable:
environment: - NIMBLE_EXECUTION_QUEUE_SIZE=5 |
Setting the queue size to 30 will add a maximum of 1 second of latency for a 30fps channel or 6 seconds of latency for a 5fps channel during network congestion. For sites with network congestion it is recommended to set this value to 5.
In the event history, the count seen in table is not the exactly same when the images are retrieved.
No workaround, will be fixed in next release.
Triggering storage purge of a particular channel is not deactivating the activated alert of that channel.
No workaround, will be fixed in the upcoming release.
Site Reports table shows the total notifications count as 0 even though there are notifications that are being sent.
No workaround, will be fixed in the upcoming release.
Missing Post will only receive one notification when there is switch from having detections to a blank frame with no bounding boxes in the video stream. Repeated notifications don’t get sent as long as video frames are empty when on demand feature is on.
No workaround, will be fixed in the upcoming release.
While installing the vas-portal using the mcutils command i.e. mcutils install vas-portal
, the installation fails sometimes.
Please run the vas portal installer command again, this will install the portal successfully.
Contextual rules consisting of multiple alert conditions using AND, OR is not supported. In the current release, the combined/composite rule is an experimental feature not guaranteed to work with all combinatorial logic reliably. Currently its recommended to create rule consisting of single alert only.
No workaround, this feature will be stabilized in the upcoming release.